10-40 KVA 3:3, 3:1 | 30KVA/27KW or 30KW
Netcon 30 KVA 3:3 Phase Tower Mount Online UPS is a high-capacity, industrial-grade power backup system designed for large-scale critical applications. With a 3-phase input and 3-phase output configuration, it ensures balanced power distribution, high efficiency, and continuous protection for mission-critical systems in data centers, healthcare, telecom, and industrial operations. UPS is CE Certified and fully compliant with EMC & IEC safety and performance standards, ensuring global compatibility, safety, and reliability.
Powered by True Online Double Conversion Technology, it delivers uninterrupted, pure, and stable power with zero transfer time, ensuring complete protection against power fluctuations, surges, and blackouts. The External Battery Type design allows for the connection of scalable battery banks, offering customizable and extended backup times to meet specific operational needs. Its advanced protection features, high efficiency (up to 95%), and scalable runtime make it a trusted power solution for industries where power continuity is critical.
This UPS offers customizable backup duration, flexible battery expansion, and smart remote monitoring, making it a versatile choice for large-scale, power-intensive applications in data centers, healthcare, telecom, industrial automation, and commercial buildings.
| Name | Certificate |
|---|---|
| EMC Certificate | View Certificate |
| LVD Certificate | View Certificate |
| EMC Test Report | View Certificate |
| LVD Test Report | View Certificate |
| MODEL | |
|---|---|
| Capacity | 30kVA/27kW or 30kW |
| INPUT | |
| Power factor | >=0.99 |
| Frequency Protection Range | 50/60Hz±10% |
| ECO Range | Same as bypass |
| Nominal Voltage (Vac) | 380/400/415Vac (3Ph+N+PE) |
| Voltage Range | 305-478 VAC (Full load): 208-478 VAC (50% load): |
| Harmonic distortion (THDi) | <=3% Linear load |
| Frequency Range | 40-70Hz (50/60Hz Auto Sensing) |
| Bypass Voltage Range | Max. voltage: 220V: +25% (Optional +10%, +15%, +20%) 230V: +20% (Optional +10%, +15%) 240V: +15% (Optional +10%) Min. voltage: -45% (Optional -20%, -30%) |
| OUTPUT | |
| Output Transfer Time | AC mode to Bat.mode - 0ms Inverter to Bypass - 0 ms |
| Overload | AC Mode : ≤110%,last 60min; ≤125%, last 10min; ≤150%, last 1 min; > 150% turn to bypass Immediately Battery Mode : ≤110%, last 10min; ≤125%, last 1min; ≤150%, last 5s; > 150% turn to bypass Immediately |
| Crest Factor | 3:1 |
| Frequency Range | Line Mode: ±1%/±2%/±4%/±5%/±10% of the rated frequency (Optional) Battery Mode: (50/60 +0.1%) Hz |
| Harmonic distortion (THDv) | <=2% Linear Load <=5% Non Linear Load |
| Power Factor | 0.9 |
| Voltage Regulation | ±1% |
| Efficiency | up to 94.5% |
| Voltage Range | 380/400/415Vac (3Ph+N+PE) |
| Output waveform | Pure Sinewave |
| PHYSICAL | |
| Approx. Net Weight | 236/43KG |
| Approx. Dimension (D×W×H) | Standard unit - 200 x 900 x 868 Long Run Unit - 250 x 580 x 655 |
| BATTERY | |
| Battery Voltage | Standard Unit : +120Vdc (3x20pcs 12V9Ah) (3x20pcs 12V7Ah optional) Long Run Unit - 10-30kVA: +96/108/120Vdc; battery quantity(16~20pcs, 16pcs default, Standard unit and 20pcs no power derating: 18pcs output power factor 0.8/0.9;16pcs output power factor 0.7/0.8) +180/192/204/216/228/240/252/264/276/288/300Vdc (30/32/34/36/38/40/42/44/46/48/50pcs supportable) |
| Charging current (Max.) | Standard Unit : 4.05A Long Run Unit 20A Max Can set according to battery capacity installed |
| ENVIRONMENT | |
| Noise level | <61dB |
| Altitude | <1500m, derating required when>1500m |
| Operating temperature | 0°C to 40°C |
| Storage temperature | -25°C~55°C |
| Humidity range | 20~95%RH @ 0~40°C (Non condensing) |
| STANDARDS | |
| Safety | IEC/EN62040-1,IEC/EN62477-1 |
| EMC | IEC/EN62040-2, IEC61000-4-2, IEC61000-4-3, IEC61000-4-4, IEC61000-4-5, IEC61000-4-6, IEC61000-4-8 |