1-3KVA, 1:1 | 2000VA / 1800W
Netcon 2KVA RackMount/Tower Online UPS is a state-of-the-art power protection solution designed to provide continuous, clean, and reliable power for critical devices. Built with True Online Double Conversion Technology, it ensures zero transfer time, making it ideal for sensitive equipment that cannot afford even a momentary power disruption. With CE and IEC Certification, Netcon UPS guarantees global safety and performance standard.
Netcon Online UPS delivers seamless backup power and surge protection for business and commercial equipment. Featuring full digital control, 110–300 Vac input, smart charging, hot-swappable batteries, ECO mode, EPO, generator compatibility, and a versatile LCD with multiple comms options, it keeps your systems safe and running efficiently.
| Name | Certificate |
|---|---|
| EMC Certificate | View Certificate |
| EMC Test Report | View Certificate |
| LVD Test Report | View Certificate |
| CE certificate | View Certificate |
| LVD Certificate | View Certificate |
| MODEL | |
|---|---|
| Capacity | 2000VA / 1800W |
| INPUT | |
| Nominal Voltage (Vac) | 208/220/230/240Vac |
| Power factor | >= 0.9 |
| Voltage Range | 110~300Vac (176~280Vac @ 100% load) |
| OUTPUT | |
| Output waveform | Pure Sinewave |
| Power Factor | >=0.9 |
| Crest Factor | 3:1 |
| Voltage Range | 208/220/230/240Vac |
| Frequency Range | Line Mode - 46~54Hz or 56~64Hz Battery Mode - (50/60±0.1%)Hz |
| Harmonic distortion (THDv) | <=3% Linear Load <=5% Non Linear Load |
| Transfer time | AC mode to Bat.mode - 0ms Inverter to Bypass - 4 ms (Typical) |
| Voltage Regulation | ±1% |
| PHYSICAL | |
| Approx. Dimension (D×W×H) | 440 x 460 x 86.5 |
| Approx. Net Weight | 19.5KG |
| BATTERY | |
| Capacity (Standard unit) | 9Ah/12V (7Ah/12V optional) |
| Typical recharging time | 4 hours (to 90% of full capacity) |
| Charging current (Max.) | 1A |
| Battery Number | 4-6 |
| Charging voltage | 54.8Vdc±1% or 82.2Vdc±1% |
| ENVIRONMENT | |
| Noise level | <1500m,derating required when>1500m |
| Altitude | <50dB at 1 Meter |
| Storage temperature | -25°C ~ 55°C |
| Humidity range | 20~95%RH @ 0°C~40°C (Non condensing) |
| Operating temperature | 0°C~40°C |
| EFFICIENCY | |
| AC mode | 91% |
| Battery mode | 87% |
| INDICATORS | |
| LCD Display (LCD version) | Line mode, Bat.mode, ECO mode, Bypass mode, Battery low voltage, Overload & UPS fault |
| LED Display (LED version) | Input voltage, Input frequency, Output voltage, Output frequency, Load percentage, Battery voltage, Inner temperature & Remaining battery backup time |
| STANDARDS | |
| EMC | IEC/EN62040-2, IEC61000-4-2, IEC61000-4-3, IEC61000-4-4, IEC61000-4-5, IEC61000-4-6, IEC61000-4-8 |
| Safety | IEC/EN62040-1, IEC/EN62477-1 |