1-3KVA, 1:1 | 1000VA / 900W
Netcon 1KVA RackMount/Tower Online UPS is a state-of-the-art power protection solution designed to provide continuous, clean, and reliable power for critical devices. Built with True Online Double Conversion Technology, it ensures zero transfer time, making it ideal for sensitive equipment that cannot afford even a momentary power disruption. With CE and IEC Certification, Netcon UPS guarantees global safety and performance standard.
Netcon Online UPS delivers seamless backup power and surge protection for business and commercial equipment. Featuring full digital control, 110–300 Vac input, smart charging, hot-swappable batteries, ECO mode, EPO, generator compatibility, and a versatile LCD with multiple comms options, it keeps your systems safe and running efficiently.
| Name | Certificate |
|---|---|
| EMC Certificate | View Certificate |
| LVD Test Report | View Certificate |
| EMC Test Report | View Certificate |
| LVD Certificate | View Certificate |
| MODEL | |
|---|---|
| Capacity | 1000VA / 900W |
| INPUT | |
| Voltage Range | 110~300Vac (176~280Vac @ 100% load) |
| Nominal Voltage (Vac) | 208/220/230/240Vac |
| Power factor | >= 0.9 |
| OUTPUT | |
| Voltage Range | 208/220/230/240Vac |
| Frequency Range | Line Mode - 46~54Hz or 56~64Hz Battery Mode - (50/60±0.1%)Hz |
| Crest Factor | 3:1 |
| Power Factor | 0.9 |
| Output waveform | Pure Sinewave |
| Transfer time | AC mode to Bat.mode - 0ms Inverter to Bypass - 4 ms (Typical) |
| Harmonic distortion (THDv) | <=3% Linear Load <=5% Non Linear Load |
| Voltage Regulation | ±1% |
| PHYSICAL | |
| Approx. Net Weight | 5.6KG / 11.3KG |
| Approx. Dimension (D×W×H) | 440 x 325 x 86.5 |
| BATTERY | |
| Battery Number | 2-3 |
| Capacity (Standard unit) | 9Ah/12V (7Ah/12V optional) |
| Charging current (Max.) | 6A/12A |
| Typical recharging time | 4 hours (to 90% of full capacity) |
| Charging voltage | 27.4Vdc±1% or 41.1Vdc±1% |
| ENVIRONMENT | |
| Operating temperature | 0°C~40°C |
| Storage temperature | -25°C ~ 55°C |
| Humidity range | 20~95%RH @ 0°C~40°C (Non condensing) |
| Noise level | <50dB at 1 Meter |
| Altitude | <1500m,derating required when>1500m |
| EFFICIENCY | |
| Battery mode | 85% |
| AC mode | 89% |
| INDICATORS | |
| LCD Display (LCD version) | Line mode, Bat.mode, ECO mode, Bypass mode, Battery low voltage, Overload & UPS fault |
| LED Display (LED version) | Input voltage, Input frequency, Output voltage, Output frequency, Load percentage, Battery voltage, Inner temperature & Remaining battery backup time |
| STANDARDS | |
| Safety | IEC/EN62040-1,IEC/EN62477-1 |
| EMC | IEC/EN62040-2, IEC61000-4-2, IEC61000-4-3, IEC61000-4-4, IEC61000-4-5, IEC61000-4-6, IEC61000-4-8 |