Line Interactive UPS | Micropower 1200
Netcon Line-Interactive UPS is specially designed for personal computers and versatile applications. Its lightweight, compact design makes it an ideal choice for environments with limited workspace. Equipped with one boost and one buck AVR, it ensures stabilized input voltage. The built-in DC start function allows the UPS to start even without an AC power supply, enhancing usability.
Line-Interactive UPS with simulated sinewave output provides seamless backup power during outages and protects against unsafe voltage fluctuations, surges, and spikes. Advanced microprocessor control, combined with internal self-diagnostic technology, guarantees excellent performance and high reliability.
Compliance & Standards
| MODEL | |
|---|---|
| Capacity | 1200 VA/720 W |
| INPUT | |
| Operating frequency range (Hz) | 60/50Hz (Auto sensing) |
| Operating voltage range (Vac) | 81~145 Vac/162~290 Vac |
| Nominal Voltage (Vac) | 110/120 Vac or 220/230/240 Vac |
| OUTPUT | |
| Frequency Range | 60/50Hz ±1 Hz |
| AC Voltage Regulation (Batt. Mode) (%) | ±10 |
| Waveform | Simulated Sinewave |
| Transfer time | Typical 2-6ms, 10ms Max. |
| PHYSICAL | |
| Performance | IEC/EN 62040-3 |
| Approx. Dimension (D×W×H) | 353×149×162mm |
| Approx. Net Weight | 8.4 |
| EMC | IEC/EN 62040-2; IEC 61000-4-2; IEC 61000-4-3; IEC 61000-4-4; IEC 61000-4-5; IEC 61000-4-6; IEC 61000-4-8 |
| Safety | IEC/EN 62040-1; IEC/EN 60950-1 |
| BATTERY | |
| Battery Type | 12 V/7 Ah×2 |
| Battery Voltage | 24 Vdc |
| Battery Mode | Sounding every 10 seconds |
| Typical recharging time | 6~8 hours recover to 90% capacity |
| ENVIRONMENT | |
| Noise level (dB) | <45 |
| Humidity range (%) | 0 ~ 90 |
| INDICATORS | |
| LED Display (LED version) | AC Mode, Battery Mode, Overload, Fault |
| LCD Display (LCD version) | AC Mode, Battery Mode, Load Level, Battery Level, Input Voltage, Output Voltage, Overload, Fault, and Battery Low |
| Battery mode | Sounding every 10 seconds |
| Low Battery | Sounding every second |
| Battery Fault | Continuously sounding |
| Battery Replacement Alarm | Sounding every 2 seconds |
| Overload | Sounding every 0.5 second |
| OTHERS | |
| Protection | Overload, Breaker |
| SYSTEM FEATURES | |
| Overload | Sounding every 0.5 second |
| Communication interface | USB or RS232(Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7, Linux, Unix, and MAC) |
| Communication | USB or RS232(Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7, Linux, Unix, and MAC) |
| Protection | Short circuit, Overload, Overcharge and over discharge protection |