Netcon
MULTI - CONDUCTOR CABLE SHIELDED CABLE

MULTI - CONDUCTOR CABLE SHIELDED CABLE

Hybrid Control Cables | 22 AWG

  • Type : Media Control, 1 Pair 22 AWG TC, 2 Cond. 18 AWG, Riser
  • Conductor :  TC - Tinned Copper
  • Outer Shield Material : TC - Tinned Copper
  • Outer Jacket Material :  LSZH Jacket
  • Inner Shield Material :  Bi-Laminate (Alum+Poly) 
  • Insulation :  PVC - Polyvinyl Chloride, PE - Polyethylene (Foam) 
  • Pair Colour Code :  Red & Black
  • Standard Put Up Length: 305-500 M 
Applications: Industrial Automation, Building Automation Systems, RS-485 Networks & Data Transmission, Power & Control Cabling Environments requiring EMI/RFI protection

Multimedia Control Cable, 1 Pair 22 AWG stranded (7x30) tinned copper conductor (data) with FPE insulation, individually foil shielded with drain wire, plus 2 Conductor 18 AWG stranded (16x30) tinned copper conductors (power) with HDPE insulation, shielded with Al. foil and drain, riser-rated LSZH jacket in grey. The construction ensures reliable signal integrity and robust power delivery, with superior EMI protection. As shown in the image, the cable features tinned copper conductors, HDPE/FPE insulation, individual and overall Al. foil shields, drain wire, PET separator, rip cord, and a durable LSZH jacket for enhanced safety and performance

Name Certificate
Test Report View Certificate
ROHS Certificate View Certificate
IEC Certificate View Certificate
CE Certificate View Certificate
PHYSICAL
Max. Recommended Pulling Tension (N) 59.8 lbs (27.1 kg)
Max. Bend Radius (Install) (mm) 2.5 in (64 mm)
Operating Temperature (ºC) -20°C to +75°C
STANDARDS
STANDARDS Flammability / Fire Resistance: UL1666 Vertical Shaft, FT4, IEC 60332-1-2 | NEC / Compliance: CM | CPR Euroclass: Eca | European Directive Compliance: EU CE Mark, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) | APAC Compliance: RoHS II (GB/T 26572-2011)
ELECTRICAL
Voltage UL Voltage Rating 300 V
Elements Pairs | Conductor DCR 16.3 Ohm/1000 ft (53.5Ohm/km) | Capacitance Cond-to-Cond 14 pF/ft (46 pF/m) | Capacitance Cond-to- other (conds + shield) 38 pF/ft (120 pF/m) | Characteristic Impedence, 100 Ohms | Max Current 3.8 Amps per Conductor at 25°C (22 AWG); 7.2 Amps per Conductor at 25°C (18 AWG)
DESIGN
Conductor | Pair(s) 1 | 22 AWG | 7 x 30 strands | TC - Tinned Copper | Conductor(s) | 2 | 18 AWG | 19 x 30 strands | TC - Tinned Copper
Insulation | Pair(s) | PE - Polyethylene (Foam) | Thickness 0.025 in (0.64 mm) | Insulation diameter 0.079 in (2.0 mm) | Colour code Blue & White, Red & Black | HDPE jacket | Conductor(s) PVC - Polyvinyl Chloride| Thickness 0.013 in (0.33 mm)| insulation diameter 0.073 in (1.9 mm) | Colour Code Red & Black
Sheath Material Inner shield - Shield Type Bi-Laminate (Alum+Poly) 100% coverage 24 AWG (7 x 32) | Tinned Copper (TC)